Knowledge Page Saro Cleynenbreugel, Elise Chalcraft, Abhay Villa

Troubleshooting

Stuff that can go wrong with Aquaponics

Here I give a overview of troubleshooting a broken aquaponics system wether it is dying fish or a faulty siphon.

Storm Damage

If there is damage to the greenhouse, discuss with Willem Velthoven and Saro Cleynenbreugel whether to call Broers Hobbykassen. If so, you can call Bart Broers from Broers Hobbykassen on +31655838173.

The flow sensor Alarm is measuring low water flow

Pomp2 Group6.4 1.11e
----------------
ALARM:
IN1: alarm was released
IN1: low

If you get this message on your phone, be alarmed!!!
If the water flow is lower than 250 l/hr for one minute the GSM module will send a message to all the programmed numbers in the list giving an 'IN1: low' message. Water might be leaking out of the system or pipes were not maintained properly and water is holding in the grow beds because of it.

  1. Look for contact with the team in the Aquaponics Signal/Whatsapp group
  2. Observe in the google water flow sheet how the flow is progressing. Realtime flow can quickly be checked here.
  3. If the water flow is not recovering and it still a long time before you expect someone to be there it is important to set your mind on taking immediate action.
    - Look at personnel planning software who is working and contact the people on location. You can also try calling the general office phone number found in the contact page.
    - If this does not work out, decide who of the team saves the day.

Power-failure Alarm

Pomp2 Group6.4 1.11e
----------------
ALARM:
Power Low !!!
Accu: 100%
Voltage: 0.4V

If you get this message on your phone, be alarmed!!! The procedure is as a flow alarm message (IN1: low)
This happens when one of the two GSM power alarm does not get power. Reasons can be:

  1. A short circuit or earth leakage is made, faulty heater or water in one of the socket boxes. In this case, typically only one of the Power alarms is triggered. You can verify water flow looking here or you Login on the D-Link webcam app and check if you see/hear the water flowing in the last tank in the back (fishtank nr. 1), login info can be found here.
  2. You get messages from two GSM Power Alarms, the mains is off because of a short circuit somewhere else in the building or the mains in the whole street is off. The cause being in the Aquaponics container has shown nihil.
    - Check the power cut procedure 

The fish are not eating

  1. Check water temperature
  2. Check for dead fish
  3. Check quality
  4. Check water flow throughout the system

Heater not working

  1. Check what the temperature is set on
  2. If the sensor is broken replace the sensor (NTC sensor 10k ohm), make sure power is off before replacing
  3. If the heater is broken replace the heater (1000W dompelaar), make sure the power is off before replacing

Is the growbed overflowing?

This can happen if you for example just refilled the sump tank, replug the pumps that were off for a while or you unclogged a nozzle of one of the water pipes filling the grow-bed in the top. The Bottom grow-bed can just not keep up with the drainage of the top two grow-bed since probably they are all filled up with water at the moment of restoring syphoning.

  1. Inspect the inside of the syphon, there could be roots growing inside
  2. Within a grow-bed see if the water can flow freely from the water-inlet to the spot of the syphon, typically across.
  3. Fill the sump tank to make up for the water loss
  4. A more permanent fix might be to make the 20mm pipes of the syphons all as short as the shortest pipe. Another option might be increasing the diameter of the syphon of the bottom grow-beds.

Does the water in the fishtanks seem higher than normal?

  1. Clean the drainage pipes, especially the pipe that penetrates the fishtanks is problematic.
  2. Make sure you don't overfeed (the fish don't eat everything) this will put a lot of fatty waste in the water and tends to stick on the inside of the pipes

Is the pump not pumping?

  1. Check the power group connected to that pump, the sockets are numbered and this corresponds with the electrical board in the back of the container.
  2. The 'dry pumping failsafe shutdown' is activated. In this case, unplug the pump from the mains and replug it after 30 seconds
  3. The pump is not fully under the water and is sucking air. Submerge the pump and make sure it stays there, cleaning the filter can help with this. Also, top up the sump tank with water.
  4. Open the pump and inspect for errors.
  5. The pump is broken beyond repair. Order a new pump.

Is the water flow to the grow-beds failing?

  1. Clean the pipes
  2. See Pump is not pumping. (above this point)

Enlarge

Catfish choked in his friend - Els Engel